EUX raw data

Overview

Retrieving the EUX raw data

Cleaning the data (Data retention)

Additional resources

Overview

To enhance debuggability and facilitate root cause analysis, the EUX raw timer data can be essential. Login Enterprise stores the raw data by default, and the data retention can be adjusted based on your specific needs. This article provides instructions on how to retrieve the EUX raw data and how to change the data retention period.

Retrieving the EUX raw data

You can retrieve the EUX raw data via the Public API with the following request (the testRunId can either be a Load test or a Continuous test Id):

GET https://appliance.loginvsi.com/publicApi/v7-preview/test-runs/{testRunId}/eux-script-executions

The API will return all the EUX measurements for each user session. Below, is an example of how the response is structured:

{
"items": [
{
"userSessionId": "3b9db89e-605a-4026-94c7-d2ebc5a3a113",
"startTime": "2023-01-23T15:29:13.671912Z",
"endTime": "2023-01-23T15:29:35.763588Z",
"successful": true,
"euxMeasurements": [
{
"timestamp": "2023-01-23T15:29:13.921948Z",
"timer": "paintStart",
"duration": 237
},
{
"timestamp": "2023-01-23T15:29:22.74797Z",
"timer": "wordPadStart",
"duration": 387
},
{
"timestamp": "2023-01-23T15:29:16.221501Z",
"timer": "wordPadTypeText",
"duration": 301
},
{
"timestamp": "2023-01-23T15:29:16.94025Z",
"timer": "sysCreateSmallFiles",
"duration": 1628
},
{
"timestamp": "2023-01-23T15:29:17.991151Z",
"timer": "sysZipFilesHigh",
"duration": 4385
},
{
"timestamp": "2023-01-23T15:29:30.60116Z",
"timer": "sysCpuOperations",
"duration": 2169
},
{
"timestamp": "2023-01-23T15:29:31.632691Z",
"timer": "sysZipFilesFast",
"duration": 1991
}
]
}

Cleaning the EUX data (Data retention)

You can configure the data retention period for EUX raw data, ranging from 1 to 9999 days. Customizing this setting is crucial to manage storage resources effectively. New installations and upgrades default to a 30-day retention period, but any customizations persist through subsequent upgrades.

To adjust the EUX raw data:

  1. In the Login Enterprise sidebar menu, navigate to Other > System.
  2. In System, click General.
  3. In Data retention, configure EUX raw data.

Frame 258.png

Additional resources